CCISS_VOL_STATUS(8)					   CCISS_VOL_STATUS(8)



NAME
       cciss_vol_status  -  show status of logical drives attached to HP Smar
       tarray controllers

SYNOPSIS
       cciss_vol_status [OPTION] [DEVICE]...

DESCRIPTION
       Shows the status of logical drives configured  on  HP  Smartarray  con
       trollers.

OPTIONS
       -p, --persnickety
	      Without  this  option,  device  nodes  which can't be opened, or
	      which are not found  to  be  of  the  correct  device  type  are
	      silently	 ignored.    This   lets   you	use  wildcards,  e.g.:
	      cciss_vol_status /dev/sg* /dev/cciss/c*d0, and the program  will
	      not complain as long as all devices which are found to be of the
	      correct type are found to be  ok.   However,  you  may  wish  to
	      explicitly list the devices you expect to be there, and be noti
	      fied if they are not there (e.g. perhaps a PCI  slot  has  died,
	      and   the   system   has	 rebooted,   so  that  what  was  once
	      /dev/cciss/c1d0 is no longer there at all).   This  option  will
	      cause the program to complain about any device node listed which
	      does not appear to be the right device type, or is not openable.

       -C, --copyright
	      If stderr is a terminal, Print  out  a  copyright  message,  and
	      exit.

       -q, --quiet
	      This  option  doesn't  do  anything.   Previously,  without this
	      option and if stderr is a terminal, a copyright message precedes
	      the  normal  program output.  Now, the copyright message is only
	      printed via the -C option.

       -s     Query each physical drive for  S.M.A.R.T	data  and  report  any
	      drives in "predictive failure" state.

       -u, --try-unknown-devices
	      If  a  device has an unrecognized board ID, normally the program
	      will not attempt to communicate with it.	In case you have  some
	      Smart  Array  controller	which  is newer than this program, the
	      program may not recognize it.  This option permits  the  program
	      to  attempt  to interrogate the board even if it is unrecognized
	      on the assumption that it is in fact a Smart Array of some kind.

       -v, --version
	      Print the version number and exit.

       -x, --exhaustive
	      Deprecated.  Previously, it "exhaustively" searched for  logical
	      drives,  as,  under some circumstances some logical drives might
	      otherwise be missed.  This option no longer  does  anything,  as
	      the  algorithm for finding logical drives was changed to obviate
	      the need for it.

DEVICE
       The DEVICE argument indicates which RAID controller is to  be  queried.
       Note, that it indicates which RAID controller, not which logical drive.

       For the cciss driver, the "d0" nodes matching "/dev/cciss/c*d0" are the
       nodes which correspond to the RAID controllers.	(See note  1,  below.)
       It  is  not  necessary to invoke cciss_vol_status on each logical drive
       individually, though if you do this, each time it will report the  sta
       tus of ALL logical drives on the controller.

       For  the  hpsa driver, or for fibre attached MSA1000 family devices, or
       for the hpahcisr sotware RAID driver which emulates Smart  Arrays,  the
       RAID controller is accessed via the scsi generic driver, and the device
       nodes will match "/dev/sg*"   Some variants of the "lsscsi"  tool  will
       easily  identify  which device node corresponds to the RAID controller.
       Some variants may only report the SCSI nexus (controller/bus/target/lun
       tuple.)	Some distros may not have the lsscsi tool.

       Executing  the  following  query to the /sys filesystem and correlating
       this with the contents of /proc/scsi/scsi or output of lsscsi can  help
       in finding the right /dev/sg node to use with cciss_vol_status:

       wumpus:/home/scameron # ls -l /sys/class/scsi_generic/*
       lrwxrwxrwx 1 root root 0 2009-11-18 12:31 /sys/class/scsi_generic/sg0 -> ../../devices/pci0000:00/0000:00:02.0/0000:02:00.0/0000:03:03.0/host0/target0:0:0/0:0:0:0/scsi_generic/sg0
       lrwxrwxrwx 1 root root 0 2009-11-18 12:31 /sys/class/scsi_generic/sg1 -> ../../devices/pci0000:00/0000:00:1f.1/host2/target2:0:0/2:0:0:0/scsi_generic/sg1
       lrwxrwxrwx 1 root root 0 2009-11-19 07:47 /sys/class/scsi_generic/sg2 -> ../../devices/pci0000:00/0000:00:05.0/0000:0e:00.0/host4/target4:3:0/4:3:0:0/scsi_generic/sg2
       wumpus:/home/scameron # cat /proc/scsi/scsi
       Attached devices:
       Host: scsi0 Channel: 00 Id: 00 Lun: 00
	 Vendor: COMPAQ   Model: BD03685A24	  Rev: HPB6
	 Type:	 Direct-Access			  ANSI	SCSI revision: 03
       Host: scsi2 Channel: 00 Id: 00 Lun: 00
	 Vendor: SAMSUNG  Model: CD-ROM SC-148A   Rev: B408
	 Type:	 CD-ROM 			  ANSI	SCSI revision: 05
       Host: scsi4 Channel: 03 Id: 00 Lun: 00
	 Vendor: HP	  Model: P800		  Rev: 6.82
	 Type:	 RAID				  ANSI	SCSI revision: 00
       wumpus:/home/scameron # lsscsi
       [0:0:0:0]    disk    COMPAQ   BD03685A24       HPB6  /dev/sda
       [2:0:0:0]    cd/dvd  SAMSUNG  CD-ROM SC-148A   B408  /dev/sr0
       [4:3:0:0]    storage HP	     P800	      6.82  -

       From  the  above  you  can  see that /dev/sg2 corresponds to SCSI nexus
       4:3:0:0, which corresponds to the HP P800  RAID	controller  listed  in
       /proc/scsi/scsi.

EXAMPLE
	    [root@somehost]# cciss_vol_status -q /dev/cciss/c*d0
	    /dev/cciss/c0d0: (Smart Array P800) RAID 0 Volume 0 status: OK.
	    /dev/cciss/c0d0: (Smart Array P800) RAID 0 Volume 1 status: OK.
	    /dev/cciss/c0d0: (Smart Array P800) RAID 1 Volume 2 status: OK.
	    /dev/cciss/c0d0: (Smart Array P800) RAID 5 Volume 4 status: OK.
	    /dev/cciss/c0d0: (Smart Array P800) RAID 5 Volume 5 status: OK.
	    /dev/cciss/c0d0: (Smart Array P800) Enclosure MSA60 (S/N: USP6340B3F) on Bus 2, Physical Port 1E status: Power Supply Unit failed
	    /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 0 status: OK.
	    /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 1 status: OK.
	    /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 2 status: OK.
	    /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 3 status: OK.
	    /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 4 status: OK.
	    /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 5 status: OK.
	    /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 6 status: OK.
	    /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 7 status: OK.

	    [root@someotherhost]# cciss_vol_status -q /dev/sg0 /dev/cciss/c*d0
	    /dev/sg0: (MSA1000) RAID 1 Volume 0 status: OK.   At least one spare drive.
	    /dev/sg0: (MSA1000) RAID 5 Volume 1 status: OK.
	    /dev/cciss/c0d0: (Smart Array P800) RAID 0 Volume 0 status: OK.

	    [root@localhost]# ./cciss_vol_status -s /dev/sg1
	    /dev/sda: (Smart Array P410i) RAID 0 Volume 0 status: OK.
		  connector 1I box 1 bay 1		   HP	   DG072A9BB7				    B365P6803PCP0633	 HPD0 S.M.A.R.T. predictive failure.
	    [root@localhost]# echo $?
	    1

	    [root@localhost]# ./cciss_vol_status -s /dev/cciss/c0d0
	    /dev/cciss/c0d0: (Smart Array P800) RAID 0 Volume 0 status: OK.
		  connector 2E box 1 bay 8		   HP	   DF300BB6C3				3LM08AP700009713RXUT	 HPD3 S.M.A.R.T. predictive failure.
	    /dev/cciss/c0d0: (Smart Array P800) Enclosure MSA60 (S/N: USP6340B3F) on Bus 2, Physical Port 2E status: OK.


DIAGNOSTICS
       Normally,  a logical drive in good working order should report a status
       of "OK."  Possible status values are:

       "OK." (0) - The logical drive is in good working order.

       "FAILED." (1) - The logical drive has failed,  and  no  i/o  to	it  is
       poosible.
	      Additionally, failed drives will be identified by connector, box
	      and bay, as well as vendor, model, serial number,  and  firmware
	      revision.

       "Using interim recovery mode." (3) - One or more drives has failed,
	      but  not	so  many that the logical drive can no longer operate.
	      The failed drives should be replaced as soon as possible.

       "Ready for recovery operation." (4) -  Failed drive(s) have been
	      replaced, and the controller is about to begin rebuilding redun
	      dant parity data.

       "Currently recovering." (5) - Failed drive(s) have been replaced,
	      and  the	controller  is	currently  rebuilding redundant parity
	      information.

       "Wrong physical drive was replaced." (6) - A drive has failed, and
	      another (working) drive was replaced.

       "A physical drive is not properly connected." (7) - There is some
	      cabling or backplane problem in the drive enclosure.

       (From fwspecwww.doc, see cpqarray project on sourceforge.net):
	      Note: If the unit_status value is 6 (Wrong  physical  drive  was
	      replaced) or 7 (A physical drive is not properly connected), the
	      unit_status of all  other  configured  logical  drives  will  be
	      marked as 1 (Logical drive failed). This is to force the user to
	      correct the problem and to insure that once the problem is  cor
	      rected,  the  data  will	not  have  been  corrupted by any user
	      action.

       "Hardware is overheating." (8) - Hardware is too hot.

       "Hardware was overheated." (9) - At some point in the past,
	      the hardware got too hot.

       "Currently expannding." (10) - The controller is currently in the
	      process of expanding a logical drive.

       "Not yet available." (11) - The logical drive is not yet finished
	      being configured.

       "Queued for expansion." (12) - The logical drive will be expended
	      when the controller is able to begin working on it.

       Additionally, the following messages may appear regarding  spare  drive
       status:

	    "At least one spare drive designated"
	    "At least one spare drive activated and currently rebuilding"
	    "At least one activated on-line spare drive is completely rebuilt on this logical drive"
	    "At least one spare drive has failed"
	    "At least one spare drive activated"
	    "At least one spare drive remains available"
       Active spares will be identified by connector, box and bay, as well
       as by vendor, model, serial number, and firmware revision.

       For  each logical drive, the total number of failed physical drives, if
       more than zero, will be reported as:

	    "Total of n failed physical drives detected on this logical drive."

       with "n" replaced by the actual number, of course.

       "Replacement" drives -- newly inserted drives that replace a previously
       failed drive but are not yet finished rebuilding -- are also identified
       by connector, box and bay, as well as by vendor, model, serial  number,
       and firmware revision.

       If  the -s option is specified, each physical drive will be queried for
       S.M.A.R.T data, any any drives in  predictive  failure  state  will  be
       reported,  identified  by  connector,  box  and bay, as well as vendor,
       model, serial number, and firmware revision.

       Additionally failure conditions of disk enclosure fans, power supplies,
       and temperature are reported as follows:

	    "Fan failed"
	    "Temperature problem"
	    "Door alert"
	    "Power Supply Unit failed"

FILES
       /dev/cciss/c*d0 (Smart Array PCI controllers using the cciss driver)
       /dev/sg*  (Fibre  attached  MSA1000  controllers  and  Smart Array con
       trollers using the hpsa driver or hpahcisr software RAID driver.)

EXIT CODES
       0 - All configured logical drives queried have status of "OK."

       1 - One or more configured logical drives  queried  have  status  other
       than "OK."

AUTHOR
       Written by Stephen M. Cameron

REPORTING BUGS
       MSA500 G1 logical drive numbers may not be reported correctly.

       I've seen enclosure serial numbers contain garbage.

       Report bugs to <steve.cameron@hp.com>

COPYRIGHT
       Copyright  2007 Hewlett-Packard Development Company, L.P.
       This is free software; see the source for copying conditions.  There is
       NO warranty; not even for MERCHANTABILITY or FITNESS FOR  A  PARTICULAR
       PURPOSE.

SEE ALSO
       http://cciss.sourceforge.net

note 1
       The  /dev/cciss/c*d0  device  nodes of the cciss driver do double duty.
       They serve as an access point to both the RAID controllers, and to  the
       first   logical	 drive	 of  each  RAID  controller.   Notice  that  a
       /dev/cciss/c*d0 node will be present for each  controller  even	if  no
       logical	drives are configured on that controller.  It might be cleaner
       if the driver had a  special  device  node  just  for  the  controller,
       instead	of making these device nodes do double duty.  It has been like
       that since the 2.2 linux kernel timeframe.  At that time, device  major
       and  minor nodes were statically allocated at compile time, and were in
       short supply.  Changing this behavior at this point would break lots of
       userland programs.